Honeywell / VISTA-128 BPT
Allows the user to Arm/Disarm partitions of the alarm system, and to receive feedback of states and notifications.
Resources
ALARM
-
Address: id of the partition [1-8]
-
States:
- MODE: ARM AWAY, ARM HOME, DISARM
- ALARM: The alarm is ringing
-
READY: Alarm ready to be armed
-
Commands:
- ARM: arm partition
- Arguments:
- MODE: AWAY, HOME, FORCE AWAY, FORCE HOME, INSTANT or MAXIMUM
- CODE: 4 digits code
- Arguments:
- DISARM: disarm partition
- Arguments:
- CODE: 4 digits code
- Arguments:
-
Events:
- _eventNotification: this event will be fired every time the alarm system sends a notification.
- Arguments:
- _code: event code (2 characters)
- _zone: zone number (3 digits)
- _timeStamp: mm/hh/dd/MM/YY (mm: minute, hh: hour, dd: day, MM: month, YY: year)
- Arguments:
ALARM_ZONE
-
Address: id of the zone [1-128]. Must have 3 digits, example: 001,012,128,…
-
States:
- OPEN: true if zone is open, false if closed
- TROUBLE: true if zone has some trouble, false otherwise
- ALARM: true if this zone has triggered the alarm
- BYPASSED: true if zone is bypassed, false otherwise
_OUTPUT
-
Address: any string, by default: Output
-
Commands:
-
_OUTPUT_CONTROL: turn on/off a single output.
- Arguments:
- _VALUE: ON / OFF
- _OUTPUT: the output number [1-96]
- Arguments:
Channel
- Baudrate: 9600
- Fc mode: none